Introducing the Tuttnauer 3870M Manual Autoclave, a robust solution crafted for the demands of busy offices requiring hefty capacity without compromising on performance. This low maintenance autoclave stands out for its ability to accommodate longer instruments or a multitude of small ones, ensuring versatility across various medical, dental, and laboratory settings.
Key Features
-
Hefty Capacity: Designed to meet the needs of the most demanding environments, the 3870M easily handles longer instruments or a large number of small instruments, providing the flexibility you need.
-
Efficient Operation: Features automatic shut-off at the end of both the sterilization and dry cycles, enhancing ease of use and energy efficiency.
-
Ultimate Safety: Equipped with a double safety locking device that prevents the door from opening while the chamber is pressurized, ensuring the safety of all users.
-
Convenience at Its Best: Comes with a 3 shelf stand for easy storage, making it a convenient addition to any workspace.
-
Simple Drainage: Includes a valve conveniently located at the front, allowing for quick and easy reservoir drainage and maintenance.
-
Durability: Boasts a long-life electro polished chamber and door, designed to endure the rigors of frequent use.
-
Overheating Protection: Features a dual safety thermostat and automatic shut-off to deliver reliable protection from overheating, safeguarding your instruments and ensuring longevity.
The Tuttnauer 3870M Manual Autoclave is not just an autoclave; it's a reliable partner in sterilization, combining capacity, performance, safety, and ease of use into one efficient package. Ideal for any setting looking to enhance its sterilization capabilities with a dependable, user-friendly solution.
Sterilization Programs
Standard unwrapped cycle
- Hot start: 23 min.
- Cold Start 32 min.
Cycle times are approximate and may vary depending on instrument loads.
Standard full size cassette is 8” x 11” and standard half size cassette is 8” x 5.5”.
Designed to meet the most current sterilization standards
UL/EN 61010-1
FDA
ISO 13485:2003
ISO 9001:2000
Installation
Installation of Tabletop Autoclaves
Just the essential installation steps.
- Place unit on a sturdy level counter.
- Measure out the proper amount of water according to model: The Valueklave 1730M = 10-12oz 2340M, 2540M, 2540MK = 12-15oz 3870M = 24-27oz
- Pour the water in through the front door of the unit. This water should cover the bottom of the chamber up to the groove in the front.
- If needed adjust the front leveling feet to achieve the necessary pitch.
- Fill the Reservoir with distilled water
- The unit is ready to operate.